Search results for "Hydrophilic interaction chromatography"

showing 10 items of 34 documents

Towards comprehensive non-target screening using heart-cut two-dimensional liquid chromatography for the analysis of organic atmospheric tracers in i…

2021

Abstract Non-target screening of secondary organic aerosol compounds in ice cores is used to reconstruct atmospheric conditions and sources and is a valuable tool to elucidate the chemical profiles of samples with the aim to obtain as much information as possible from one mass spectrometric measurement. The coupling of mass spectrometry to chromatography limits the results of a non-target screening to signals of compounds within a certain polarity range based on the utilized stationary phases of the columns. Comprehensive two-dimensional liquid chromatography (LCxLC) introduces a second column of different functionality to enable the analysis of a broader range of analytes. Conventional LCx…

AerosolsDetection limitChromatography Reverse-PhaseAnalyteChromatographyChemistryHydrophilic interaction chromatographyOrganic ChemistryGeneral MedicineRepeatabilityMass spectrometrySnowBiochemistryMass SpectrometryAnalytical ChemistryAerosolVolume (thermodynamics)Hydrophobic and Hydrophilic InteractionsChromatography LiquidJournal of Chromatography A
researchProduct

Surface charge fine tuning of reversed-phase/weak anion-exchange type mixed-mode stationary phases for milder elution conditions.

2015

A series of new mixed-mode reversed-phase/weak anion-exchange (RP/WAX) phases have been synthesized by immobilization of N-undecenyl-3-α-aminotropane onto thiol-modified silica gel by thiol-ene click chemistry and subsequent introduction of acidic thiol-endcapping functionalities of different type and surface densities. Click chemistry allowed to adjust a controlled surface concentration of the RP/WAX ligand in such a way that a sufficient quantity of residual thiols remained unmodified which have been capped by thiol click with either 3-butenoic acid or allylsulfonic acid as co-ligands. In another embodiment, performic acid oxidation of N-undecenyl-3-α-aminotropane-derivatized thiol-modifi…

AnionsAcetonitrilesSulfonic acidBiochemistryAnalytical Chemistrychemistry.chemical_compoundEndcappingSulfhydryl Compoundschemistry.chemical_classificationWaxChromatography Reverse-PhaseChromatographyPerformic acidElutionSilica gelHydrophilic interaction chromatographyOrganic ChemistryGeneral MedicineChromatography Ion ExchangeSilicon DioxideMixed-mode chromatographychemistryvisual_artvisual_art.visual_art_mediumSolventsClick ChemistryHydrophobic and Hydrophilic InteractionsTropanesJournal of chromatography. A
researchProduct

N-Propyl-N′-2-pyridylurea-modified silica as mixed-mode stationary phase with moderate weak anion exchange capacity and pH-dependent surface charge r…

2018

Herein, we present a novel silica-based stationary phase modified with N-propyl-N'-2-pyridylurea selector. Due to the weakly basic properties of the pyridine selector and the presence of residual silanols after selector immobilization, a zwitterionic surface with a pI observed at approximately pH 5.5 was measured by electrophoretic light scattering in pH-dependent ζ-potential determinations. The capability of the new N-propyl-N'-2-pyridylurea-modified silica to serve as mixed-mode stationary phase was investigated. For this purpose, it was characterized under RP and HILIC conditions using test mixtures. Subsequent classification of this stationary phase in comparison to in-house and commerc…

AnionsPyridinesSurface PropertiesSilicon dioxideAnalytical chemistryUridine Triphosphate02 engineering and technology01 natural sciencesBiochemistryUridine DiphosphateAnalytical Chemistrychemistry.chemical_compoundUreaSurface chargeAnion Exchange ResinsChromatographyIon exchangeChemistryElutionHydrophilic interaction chromatography010401 analytical chemistryOrganic ChemistryGeneral MedicineHydrogen-Ion ConcentrationChromatography Ion ExchangeSilicon Dioxide021001 nanoscience & nanotechnology0104 chemical sciencesMixed-mode chromatographyElectrophoretic light scatteringUridine Monophosphate0210 nano-technologySelectivityHydrophobic and Hydrophilic InteractionsJournal of Chromatography A
researchProduct

Stable-bond polymeric reversed-phase/weak anion-exchange mixed-mode stationary phases obtained by simultaneous functionalization and crosslinking of …

2019

Abstract A polymeric reversed-phase/weak anion exchange (Poly-RP/WAX) mixed-mode stationary phase has been prepared by coating of a poly(3-mercaptopropyl)methylsiloxane film on vinyl-modified silica (100 A, 5 μm) and simultaneous in situ functionalization with N-(10-undecenoyl)-3-aminoquinuclidine as well as crosslinking to the vinyl silica surface by solventless thiol-ene double click reaction. Such bonding chemistry showed greatly enhanced stability compared to brush-type analogs with bifunctional siloxane bonding to silica. Solid-state 29Si-CP/MAS NMR confirmed the immobilization of the siloxane layer. pH-Dependent ζ-potential determinations revealed a high anion-exchange capacity over t…

AnionsSiloxanesPolymersSulfonic acid010402 general chemistry01 natural sciencesBiochemistryAnalytical Chemistrychemistry.chemical_compoundEndcappingPolymer chemistrySulfhydryl CompoundsEne reactionchemistry.chemical_classificationChromatography Reverse-PhaseChromatographyChemistryElutionHydrophilic interaction chromatography010401 analytical chemistryOrganic ChemistryGeneral MedicineChromatography Ion Exchange0104 chemical sciencesMixed-mode chromatographySiloxaneSurface modificationClick ChemistryPolyvinylsJournal of chromatography. A
researchProduct

Micellar Liquid Chromatography: Fundamentals

2015

The reversed phase liquid chromatography (RPLC) mode with surfactant above the critical micellar concentration (CMC) has been called micellar liquid chromatography (MLC). In pure micellar systems, the retention behavior is explained by considering three phases or environments: surfactant-modified stationary phase, bulk aqueous solvent, and micellar pseudo-phase. Surfactant adsorption on the porous RPLC packing affects chromatographic retention, owing to the change of diverse surface properties of the stationary phase. In pure micellar systems, the retention behavior is explained by considering three phases or environments: surfactant-modified stationary phase, bulk aqueous solvent, and mice…

Aqueous solutionColumn chromatographyAqueous normal-phase chromatographyChemistryMicellar liquid chromatographyHydrophilic interaction chromatographytechnology industry and agricultureAnalytical chemistrylipids (amino acids peptides and proteins)macromolecular substancesReversed-phase chromatographyMicelleMicellar electrokinetic chromatography
researchProduct

Highly efficient separation of amines by electrokinetic chromatography using resorcarene-octacarboxylic acids as pseudo-stationary phases

1998

Abstract Resorcarene-octacarboxylic acids, macrocyclic molecules built up by four alkylidene-bridged resorcinol units, were synthesized and used as pseudostationary phases in electrokinetic chromatography (EKC). Resorcarenes provide a stable structure and good solubility in electrolytes even with organic modifiers. The high electrophoretic mobility of the resorcarene-octacarboxylic acids introduced here as pseudostationary phases is based on the eight partly deprotonated carboxylic groups. This offers a broad migration time window, which is the main parameter for the resolution of peaks. From three compounds with different alkyl chain lengths (C 1 , C 5 , C 11 ), the C 11 -resorcarene-octa-…

Carboxylic acidClinical BiochemistryKineticsCarboxylic AcidsResorcinolElectrochemistryHigh-performance liquid chromatographyBiochemistryMicellar electrokinetic chromatographyAnalytical ChemistryHomologous serieschemistry.chemical_compoundElectrokinetic phenomenaColumn chromatographyDrug DiscoveryElectrochemistryAminesDerivatizationMolecular BiologyAlkylchemistry.chemical_classificationPharmacologyChromatographyChromatographyElutionHydrophilic interaction chromatographyOrganic ChemistryResorcinolsGeneral MedicineCapacity factorKineticschemistryChromatography columnBiomedical Chromatography
researchProduct

Liquid chromatography and characterization of ether-functionalized imidazolium ionic liquids on mixed-mode reversed-phase/cation exchange stationary …

2010

Abstract A new series [CnOmmim]Cl of imidazolium cation-based ionic liquids (ILs), with an ether functional group on the alkyl side-chain, has been prepared. The possibility of analyzing the ionic liquids by high performance liquid chromatography (HPLC) was investigated on mixed-mode reversed/cation exchange stationary phase with the aqueous-acetonitrile mobile phase. Elution parameters, such as retention factor, selectivity and column efficiency, were studied as functions of mobile phase composition and pH. The ILs were characterized by elemental analysis, and infrared, UV and 1H, 13C NMR spectroscopy.

ChromatographyChemistryElutionGeneral Chemical EngineeringHydrophilic interaction chromatographyIon chromatographyAnalytical chemistryEtherGeneral ChemistryReversed-phase chromatographyHigh-performance liquid chromatographychemistry.chemical_compoundPhase (matter)Ionic liquidComptes Rendus Chimie
researchProduct

Determination of alinidine in human plasma by high-performance liquid chromatography.

1981

ChromatographyChemistryHydrophilic interaction chromatographyAdministration OralGeneral ChemistryHigh-performance liquid chromatographyClonidineColumn chromatographyHuman plasmaReference ValuesAlinidineInjections IntravenousSupercritical fluid chromatographyHumansChromatography columnChromatography High Pressure LiquidHalf-LifeJournal of chromatography
researchProduct

Chromatographic Efficiency in Micellar Liquid Chromatography: Should it Be Still a Topic of Concern?

2013

Micellar liquid chromatography (MLC) was first proposed as an attractive alternative to avoid the use of organic solvents. It was soon apparent that pure micellar solutions yield poor efficiencies. This problem was remediated by the addition of a small amount of an organic solvent. However, the general opinion of the poor peak shape has prevailed as a handicap for MLC, in spite of the fact that the hybrid mode often offers similar or even improved efficiencies (for basic compounds) relative to that attained in the hydro-organic mode. Only the efficiencies for apolar non-ionizable compounds are still clearly inferior. This work describes the type of interactions and polarity changes with org…

ChromatographyChemistryHydrophilic interaction chromatographyAnalytical chemistryFiltration and SeparationSilanol effect suppressionAnalytical ChemistryAdsorptionHybrid mobile phasesPulmonary surfactantMicellar liquid chromatographyYield (chemistry)Mass transferBand broadeningMicellar solutionsMass transferenceWettingMicellar liquid chromatographyStationary phase architecture and wettingSeparation & Purification Reviews
researchProduct

Non-porous microparticulate supports in high-performance liquid chromatography (HPLC) of biopolymers — concepts, realization and prospects

1986

ChromatographyChemistryHydrophilic interaction chromatographyOrganic ChemistryClinical BiochemistryFast protein liquid chromatographyReversed-phase chromatographyBiochemistryHigh-performance liquid chromatographyDisplacement chromatographyAnalytical ChemistryColumn chromatographyThermoresponsive polymers in chromatographyRealization (systems)Chromatographia
researchProduct